Hangzhou E-MEM Environmental Technology Co.,Ltd

Business Type:Manufacturer

Main Products: RO Membrane Water Treatment AccessoriesRO membrane for water purifierRO membrane 75 gpd Drinking water used membrane products brackish water membranenano filtration membrane elementQuality membrane manufacturer MBR water treatment plant pure water treatment for medical use hollow fiber UF membrane PVDF

view on mobile

2012-100

Smart Home Appliance & Security Firefighting & Water Safety

FOB Price:US$ 4.50 / Piece(s)

MOQ:2000 Piece(s)

Payment Method : T/T 

Keywords:

Add to Favorites

Product Category: Smart Home Appliance & Security > Firefighting & Water Safety Trademark: E-MEM
Product Package: 25pcs/carton Specifications: 2012-100
Place of Origin: China Port: Shanghai ,NIngbo



Household Reverse Osmosis Membrane Series

E-MEM household membrane components are mainly used in various household water purifiers, mineralized direct drinking machines and other small systems. Its main effect is to remove organic matter, microorganisms, viruses and most of the divalent and above metal ions in water, while retaining part of sodium, potassium, calcium, magnesium , improve the taste of purified water and maintain some mineral nutrients content.

1 High recovery rate to help consumers save water costs.
2 High performance and long element life.
3 Shipped dry for long shelf life.
4 Elements are certified by NSF International against NSF/ANSI Standard 58. 5 OEM&ODM are available.

Spiral-wound element with polyamide thin-film composite membrane


Product Specifications


        

E-MEM? Element

Active Area

Feed spacer

Thicknessmil

Permeate Flow

GPD  m3/d

Testing Pressure

Salt Rejection

%

ft2 m2

psi/MPa

EM-RO-1812-50

4.4  (0.41)

28

50   (0.19)

60  (0.41)

97.5

EM-RO-1812-75

4.4  (0.41)

28

75  (0.28)

70  (0.48)

97.5

EM-RO-2012-100

5.5  (0.51)

22

100  (0.38)

70  (0.48)

97.5

EM-RO-2012-150

7.8  (0.72)

17

150  (0.57)

70  (0.48)

97.5

EM-RO-3012-300

15.4 (1.43)

22

300  (1.14)

90  (0.62)

97.5

EM-RO-3012-500

18.0 (1.68)

17

500  (1.32)

90  (0.62)

96








1. Permeate flow and salt (NaCl) rejection based on the following standard test conditions. 250 ppm NaCl, 77°F (25°C), pH 7.5, 15% recovery.

2. Minimum salt rejection:96%.

3. Single membrane element production flow may vary ±20%.

Element Dimensions

1. Permeate flow and salt (NaCl) rejection based on the
250 ppm NaCl, 77°F (25°C), pH 7.5, 15% recovery.
2. Minimum salt rejection:96%.
3. Single membrane element production flow may vary ±20%.

following standard test conditions.

E-MEMElement

A(±2.0mm)

B(±1.0mm)

C1(±1.0mm)

C2(±1.0mm)

D(±0.1mm)

In.(mm)

In.(mm)

In.(mm)

In.(mm)

In.(mm)

EM-RO-1812-50

11.74 298

1.75 44.5

0.87 22

0.87 22

0.68OD 17OD

EM-RO-1812-75

11.74 298

1.73 44

0.87 22

0.87 22

0.68OD 17OD

EM-RO-2012-100

11.74 298

1.89 48

0.87 22

0.87 22

0.68OD 17OD

EM-RO-2012-150

11.74 298

1.89 48

0.87 22

0.87 22

0.68OD 17OD

EM-RO-3012-300

11.74 298

2.99 76

0.87 22

0.47 12

0.68OD 17OD


Operating limit

Diaphragm type

Polyamide Composite Membrane

Maximum operating temperature 

113℉(45℃)

Maximum operating pressure 

150 psi10 bar

pH range, continuous operation

3-10  a

Maximum Influent SDI

5

Free chlorine tolerance

<0.1 ppm   b

a When pH > 10, the maximum allowable temperature for continuous operation is 95℉(35℃).

b Under certain conditions, the presence of free chlorine and other oxidants will lead to premature failure of membranes. Therefore, it is recommended that the membrane be pretreated to remove residual free chlorine before water comes into contact with membranes.


The product water should be released within the first hour.
Once the membrane element is wetted, it should always remain wet.

? Users should be responsible for the effects of incompatible chemicals and lubricants on membrane components.
? Back pressure should be avoided at all times.

When the use and operation parameters of the product are refused or not provided to E-MEM, the buyer waives all other terms and conditions of quality assurance except that the terms of material, manufacturing and initial performance assurance are still valid.

Essential insurance clause excludes any indirect, joint and several, special, punitive and punitive liability for damages

The use of E-MEM products does not guarantee the removal of cysts and pathogens in water. The effective removal rate of cysts and pathogens depends on the design and operation of the whole system.


Contact Name: Mrs. YUN WANG Contact Email: sh****n@e-mem.cn
Contact Job Title: Sales Manager Contact Mob: 180***392
Contact Tel: 86-571-86989169 Contact Fax: 86-571-89056513
Address: No.26, Longquan Road, Future SCI-TECH City, Hangzhou City, Zhejiang Province, China. Website: www.e-mem.cn

Hangzhou E-MEM Environmental Technology Co., Ltd, established in 2009, which is a professional RO, NF, UF and MBR separation membrane manufacturer and exporter. It covers an area of 26000sqm and gathers R&D, manufacturing and sales as a whole.

     With advanced production equipment and technology, E-MEM reaches two million domestic RO membrane, thirty thousand RO industrial membrane elements and with 30% annual growth of annual production capacity. Certified to NSF and ISO certificate.

     E-MEM highly standardized R&D terms provide powerful technical support for the high-performance membrane products. Orderly production lines, careful selection of raw material and strictly quality control system ensure high quality of membrane products. Professional sales and service teams provide individualized pre-sales, sale, after-sales service and win good reputation among Chinese and oversea markets.

    E-MEM, warmly welcome you and we are looking forward to building successful business relationships with you in the near future.