DF508-MU PowerMonitor Module

1Summary

 

DF508-MU  Power  monitor  module  is  desgined  for  FRTU  power  module, realtime   acquisition   power   module   AC   voltag and   voltage   curren of   DC loading ,voltage and charge and discharge current of battery, and all different alarm message of power module. Moreover, it can control the activation treatment of battery and cut off protection of battery and so on, in order to realize the intelligent charging and discharging FRTU power system management.


DF508-MU Power control module can be used to manage two sets DF508 power module at the same time, in order to realize the redundancy of power system. 

 

 

2Basic Feature

 

1Environmental requirement Temperature40+70RH5%95%

Atmospheric Pressure86kPa108kPa

2power supplynominal value DC24Vscale : DC1830V

3Communication portRS485Baud rate: 4800bps

4Communication ProtocolModbus

5Analog Input

AC Voltage: AC0286V50HzAccuracy: ±0.5% DC Voltage: DC028VAccuracy: ±0.5%


 

 

Load Current05AAccuracy: ±1%

Battery Current: 0±15AAccuracy: ±1%

6I/O Input8 ChannelsDC24V

7I/O Output:

6 Channels  DC30V2A

2Channels  AC250V5A

8Dimension(mm)235×165×50

 

3Indicator light

 

POWERPower supply, normal light

RUNoperation light, normal a second light

FAULTfault lightDetect the power module failure light ACTIVATIONindicate the activation stadus of battery RXDRS485 receiving indicator

TXDRS485 transmiting indicator

 

4Terminal definition

 

NAME

NO.

DEFINITION

REMARKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1#POWER

 

1

 

Telecontrol output common port

 

Connect with VG terminal of power module 1#

 

2

 

Telcontrol activation quit

Connect with HG terminal of power module   1#

 

3

 

Fault input

Connect with VH terminal of power module   1#

 

4

Batterry activation status input

Connect with HOK terminal of power module 1#

 

5

 

Telesignalisation power

24V output positive

 

Connect with VC terminal of power module   1#

 

6

 

Telecontrol battery quit

Connect with BG terminal of power module 1#

 

7

Telecontrol activation start

Connect with HK terminal of power   module 1#

 

8

Undervoltage   alarm input of battery

Connect with VL terminal of power module 1#


 

 


 

9

AC power break alarm input

Connect with POK terminal of power module   1#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2#POWER

 

1

Telecontrol output common port

Connect with VG terminal of power module 1#

 

2

 

Telcontrol activation quit

Connect with HG terminal of power module   1#

 

3

 

Fault input

Connect with VH terminal of power module   1#

 

4

Batterry activation status input

Connect with HOK terminal of power module 1#

 

5

Telesignalisation power

24V output positive

Connect with VC terminal of power module   1#

 

6

 

Telecontrol battery quit

Connect with BG terminal of power module 1#

 

7

Telecontrol activation start

Connect with HK terminal of power   module 1#

 

8

Undervoltage   alarm input of battery

Connect with VL terminal of power module 1#

 

9

AC power break alarm

input

Connect with POK terminal of power

module 1#

 

 

 

 

 

 

NO.

NAME

DEFINITION

REMARKS

 

 

1

 

 

 

 

B-

 

 

Battery negative   terminal(connect with power module)

 

Connect with B- terminal of   1#

power module   DF508

 

2

 

Connect with B- terminal of   2#

power module   DF508

 

3

 

 

 

 

B+

 

 

Battery active   terminal(connect with power module)

Connect with B+ terminal of   1#

power module   DF508

 

 

4

 

Connect with B+ terminal of   2#

power module   DF508

 

 

5

 

 

 

 

Vo+

 

 

DC   loading active terminal(connect with power module)

 

Connect with Vo+ terminal of

1# power module DF508

 

 

6

 

Connect with Vo+ terminal of

2# power module DF508


 

 

 

7

 

 

 

 

Vo-

 

 

DC   loading negative terminal(connect with power module)

 

Connect with Vo- terminal of

1# power module DF508

 

 

8

 

Connect with Vo- terminal of

2# power module DF508

 

9

 

485-A

 

RS485 port of A

 

Connect with A terminal of

RS485

 

10

 

485-B

 

RS485 port of B

 

Connect with B terminal of

RS485

 

11

 

24V+

 

Monitoring module   power positive

 

 

Field   wiring not required,internal   has been connected   to the Vo +   Vo -

 

 

12

 

 

24V-

 

Monitoring module   power negative

13

EARTH

Protective   grounding

grounding

14

 

BAT-

 

Negative of battery

Connect with battery nagitive terminal

15

16

 

BAT+

 

Positive of battery

 

Connect with battery positive

17

 

18

 

LOAD1+

 

DC   loading No.1 positive

 

Connect with No.1 positive terminal

 

19

 

LOAD2+

 

DC   loading No.2 positive

 

Connect with No.1 positive terminal

20

 

LOAD-

 

DC   loading nagitive

 

Connect with nagitive   terminal

21

22

AC-L

AC power input

Connect with phase line   of AC

 

 

23

 

 

AC-L1

 

 

AC power output 1

 

Connect with ACL terminal of

No.1 DF508 power module

 

 

24

 

 

AC-L2

 

 

AC power output 2

 

Connect with ACL terminal of

No.2 DF508 power module

25

 

 

 

 

AC-N

 

 

 

 

AC-N

AC N

 

26

Connect with ACN terminal   of

NO.1 Power module

 

27

Connect with ACN terminal   of

NO.2 Power module

 


Contact Name: Mr Pengfei Jiang Contact Email: ji****i@dongfang-china.com
Contact Job Title: Manager Contact Mob: 136***167
Contact Tel: +86-535-5520946 Contact Fax: +86-535-5520930
Address: No.:2 Jichang Road Zhifu Yantai City Shandong Province China Website: http://www.dongfang-china.com/en/

Dongfang Electronics Co.,Ltd.(hereafter referred to as DFE) is a hi-tech business group combining research and development, production and operation, technical services and system integration, one of the major suppliers of China' s energy management system solutions, and also the key hi-tech enterprise aided by the state and Shandong Province. In 1982, we developed the first microcomputer- based Remote Terminal Unit (RTU) in China through cooperation with Shandong Industrial University, which has made us involved in power system automation field. After development of more than five decades, Dongfang Electronics has owned 18 proprietary and investment enterprises including one listed company. Dongfang Electronics has boasted the technical center and the post- -doctoral scientific research station recognized by the state, participated in the international standard formulation of International Electro technical Commission (IEC) on behalf of China, and exported the technologies and services to South America, South-east Asia, Middle East, Europe,etc. Today, Dongfang Electronics has regarded "Cherish environment, Treasure resource" as a vision to incorporate environmental protection, energy saving, safety and intelligence into business flow and to provide customers with energy system solution. By focusing on smart grid, internet of things(IOT), environmental protection and energy saving, Dongfang Electronics has provided the intelligent automation control products and solutions in terms of power generation, power transmission, power transformation, power distribution and power utilization, and has made great achievements in the research and application of Radio Frequency Identification (RFID) technology, and high/low- -voltage frequency converters, and thereby has made significant contributions to the generalization and application ofinternet of things, energy saving and consumption reduction.

Products of the same category