Business Type: Manufacturer
Main Products:Anesthesia MachineICU VentilatorCPAP SystemNitrous Oxide Sedation SystemSleep Therapy System
ID:2004101502
Category: Health & Beauty Medical Devices
MOQ:2.00 Set(s)
ICU ,mechanical, air ventilator, breathing ,respiratory ,machine, for adult and children
L/CT/TD/PWesstern Union
Brand Name:
Model Number:
Place of Origin:
Instrument classification:
Type:
Supply Ability:
100 Set/Sets per Week
Packaging Details
Wooden case
Port
Shenzhen, Shanghai
Picture Example:

Lead Time :
| Quantity(Sets) | 1 - 1 | >1 |
| Est. Time(days) | 7 | To be negotiated |





Ventilation modes: | IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV | |
Ventilator parameter | Tidal volume(Vt) | 0 ~ 2000mL |
Frequency (Freq) | 1bpm ~ 100 bpm | |
Oxygen concentration | 21%-100% | |
I/E | 4:1~1:8 | |
PEEP | 0cmH2O ~ 40 cmH2O | |
Pressure Limit | 20 cmH2O ~ 100 cmH2O | |
Monitored Parameters | Frequency (Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) | 0 mL ~ 2500 mL | |
MV | 0 L/min ~ 99 L/min | |
Airway pressure | 1mL/cmH2O ~ 1000mL/cmH2O | |
Dynamic lung compliance testing | 1mL/cmH2O ~ 1000mL/cmH2O | |
ETCO2 Concentration | 0mmHg ~ 152mmHg (0%-20%) | |
Oxygen concentration | 15 % ~ 100 % | |
ETCO2 Concentration | 0mmHg ~ 152mmHg (0%-20%) | |
Oxygen concentration | 15 % ~ 100 % | |
Oscillographs display | P-T(pressure – time) | |
F-T(flow – time) | ||
P-V loop (pressure – volume loop) | ||
V-T(volume – time ) | ||
ETCO2-T (End-tidal CO2 - time) | ||
Alarms and protection | The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ≤11.3±0.3V | |
No tidal volume | No tidal volume within 6s | |
High Minute Volume alarm | 5L/min-99L/min | |
Low Minute Volume alarm | 1L/min-30L/min | |
High Airway pressure alarm | 20cmH2O-100cmH2O | |
Low Airway pressure alarm | 0cmH2O-20cmH2O | |
High oxygen concentration alarm | 19%-100% | |
Low oxygen concentration alarm | 18%-99% | |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s | |
Suffocation warning | 5-60s | |
Fan error | Show on screen | |
Oxygen deficit | Show on screen | |
The maximum limited pressure | <12.5 kPa | |
Working conditions | Gas source | O2, AIR |
Pressure | 280kPa-600kPa | |
Voltage | 220V±22V | |
Power frequency | 50Hz ± 1Hz | |
Input power | 900VA (with air compressor) | |
250VA (without air compressor) | ||
Parking size | Main components: L 560 * W 560 * H 605 mm, G.W. : 35 KG, N.W. : 17 KG | |
Air compressor: L 670* W 700 * H 1160 mm, G.W. : 79 KG, N.W. : 46.2 KG | ||

Business Type:Manufacturer
Online Supplier