Product Category
Health & Beauty > Health Care & Medical Sanitary
Trademark
Business Type: Manufacturer
Main Products:Chemicals, Computer Products, Health & Medicine, Security & Protection
ID:2004142038
Category: Health & Beauty Health Care & Medical Sanitary
MOQ:10.00 Piece(s)
Medical VentilatorVentilator
L/CT/TD/P
| Technical parameters of double level ventilator | |||
| Ventilator type | Ventilator type | Electric control | |
| Scope of application | Treatment and titration of sleep apnea hypopnea syndrome, severe snoring, and respiratory insufficiency. | ||
| Display interface | 3.5-inch LED screen, Chinese operating system | ||
| *Ventilation mode | CPAP,S,S/T,T | ||
| Pressure range | Pressure range | 4-25cmH2O(±0.5cmH2O) | |
| Pressure accuracy | + 0.5cmH2O | ||
| Parameter setting | Delayed boost | 0-60min, set the division interval 5min | |
| Initial pressure | 4cmh2o treatment pressure / respiratory pressure setting | ||
| Therapeutic pressure | 4-20cmh2o (in CPAP mode) | ||
| Target tidal volume | 150ml - 1500ml, on / off | ||
| Maximum suction pressure | 4-25cmh2o, (can be set when the target tidal volume function is on) | ||
| Minimum suction pressure | 4-25cmh2o (not higher than suction pressure), (can be set when target tidal volume function is on) | ||
| Inspiratory phase pressure | 4-25cmH2O | ||
| Expiratory pressure | 4-25cmH2O | ||
| Expiratory decompression | Patient, off, 1-3, three adjustable | ||
| Manual voltage regulation | 0-2 gear, 0-2cmh2o (only available in CPAP mode) | ||
| Inspiratory sensitivity | 1-8 stalls | ||
| Expiratory sensitivity | 1-8 stalls | ||
| Respiratory frequency | 3-40 times / min | ||
| Inspiratory time | 0.3-3.0s | ||
| backup rate | On / off, default 10 | ||
| Pressure rise time | 1-4 stalls | ||
| Humidifier | 1-5 adjustable in 5 gears | ||
| *Titration function | Support manual and automatic pressure titration, built-in remote wireless communication module, complete the random switching of single and double level modes in the titration process, and control more than 11 ventilator parameters at the same time. | ||
| Auxiliary function | Automatic air leakage compensation, automatic startup, automatic shutdown, delayed shutdown, screen backlight adjustment | ||
| Monitoring parameters | Pressure, tidal volume, respiratory rate, minute ventilation volume, air leakage volume, inspiratory time, blood oxygen saturation | ||
| Wavy curve | Pressure time waveform, flow rate time waveform | ||
| Alarm prompt | Pipeline and mask falling off, air leakage prompt, power interruption, treatment machine failure, humidifier failure, low voltage, high respiratory rate, low respiratory rate, low minute ventilation volume, low blood oxygen, replacement of filter cotton, full SD card, re insertion of SD card | ||
| *Data management | network data | BMC + respiratory health management cloud platform | |
| SD card data | Resart NPAP data analysis software | ||
| parts | SD card | Standard | |
| SD card slot | Standard | ||
| Piping | φ 22mm, 1.8m long | ||
| face shield | Standard nose mask | ||
| Noise | Less than 30dB | ||
| environment condition | When used | During transportation and storage | |
| temperature | 5 -35 C | -20 C -55 C | |
| Atmospheric pressure | 760-1060hPa | 760-1060hPa | |
| Working hours | More than 8 hours | ||
| Power supply requirements | AC voltage | 100-240V | |
| frequency | 50Hz/60Hz | ||
| Input power | Less than 2A | ||
| Waterproof level | IP22 - drip proof equipment | ||
| Instrument size | 290mm×180mm×134mm | ||
| weight | 1.5kg (excluding humidifier) 2.5kg (including humidifier) | ||
Business Type:Manufacturer
Online Supplier