Business Type: Manufacturer
Main Products:Generator Microprocessor-based Protection DeviceMicrocomputer Monitoring SystemDiagitalized Microprocessor-based Protection Devicemicroprocessor governorMicroprocessor Excitation PanelLow Voltage SwitchgearsLow Voltage Power Distribution CubicleHV/LV Pre-assembled Substation
ID:20102827295
Category: Electrical & Power Energy Electrical Controls
MOQ:1.00 Piece(s)
Low VoltageFixed SwitchgearsCustomizable
T/T
l The cubicle is welded and assembled by the section bar. The front and rear door and the meter room door are made of the cold-roll steel sheet and processed with the CNC machining. The installation hole is modularized in E=20mm. The top and the bottom of the cubicle can access the inlet and the outlet lines, making the installation and the maintenance easy.
l The mounting plate and the mounting girder of the electrical components are fixed at the uprights at both sides of the main structure. There has provided with the doors at the front and the rear. The meter door is located at the upper part of the front panel. The secondary equipments like meters and the control switch can be mounted at doors.
l If requested by the user or the design, the incoming circuit breaker can be withdrawable or fixed;
l With the epoxy resin electrostatic spraying technology, the cubicle has great anti-corrosion capability;
l Ambient air temperature ≤+40℃ and no less than -5℃, the average temperature within 24h ≤+35℃;
l For indoor use, the elevation of using site ≤ 2000m (above this can be negotiated)
l The relative humidity should not exceed 50% at +40℃, while at lower temperatures, larger relative humidity is acceptable, e.g. 90% at +20℃. Considering the change of temperature may sometime cause the condensation, the daily average should be less than 95% and the monthly average less than 90%;
l The gradient between installation surface and vertical plane is ≤ 5°;
l The device should be installed in the location without violent vibration and impact to prevent the electrical components from corrosion.
l For special requirements, please contact the manufacturer for solution.
No. | Type | Rated volt. (V) | Rated current (A) | Rated short breaking current(KA)
| Rated short withstand current(KA)
| Rated short withstand current(KA)
| |
1 | GGD1 | 380 | A | 1000 | 15 | 15 |
30
|
B | 600(630) | ||||||
C | 400 | ||||||
2 | GGD2 | 380 | A | 1500(1600) | 30 | 30 | 63 |
B | 1000 | ||||||
C | |||||||
3 | GGD3 | 380 | A | 3150 | 50 | 50 | 105 |
B | 2500 | ||||||
C | 2000 | ||||||
No | Description | Rated current (A) | Power inlet/ outlet method | Configuration function | Dimension (mm) | Loop | Mounting type |
1 | Smart/Air CB | 630A | Busbar inlet from top/cable inlet from bottom | Power/ Bus couple | 800*600*2200 | 1 | Drawable/fixed |
2 | Smart/Air CB | 800A | Busbar inlet from top/cable inlet from bottom | Power/ Bus couple | 800*600*2200 | 1 | Drawable/fixed |
3 | Smart/Air CB | 1250A | Busbar inlet from top/cable inlet from bottom | Power/ Bus couple | 800*600*2200 | 1 | Drawable/fixed |
4 | Smart/Air CB | 1600A | Busbar inlet from top/cable inlet from bottom | Power/ Bus couple | 800*600*2200 | 1 | Drawable/fixed |
5 | Smart/Air CB | 2000A | Busbar inlet from top/cable inlet from bottom | Power/ Bus couple | 800*600*2200 | 1 | Drawable/fixed |
6 | Smart/Air CB | 2500A | Busbar inlet from top/cable inlet from bottom | Power/ Bus couple | 1000*800*2200 | 1 | Drawable/fixed |
7 | Smart/Air CB | 3150A | Busbar inlet from top/cable inlet from bottom | Power/ Bus couple | 1000*800*2200 | 1 | Drawable/fixed |
8 | Smart/Dual power switch | 630A | Busbar inlet from top/cable inlet from bottom | Dual power switch | 800*600*2200 | 1 | Drawable/fixed |
9 | Smart/Dual power switch | 800A | Busbar inlet from top/cable inlet from bottom | Dual power switch | 800*600*2200 | 2 | Drawable/fixed |
10 | Smart/Dual power switch | 1250A | Busbar inlet from top/cable inlet from bottom | Dual power switch | 800*600*2200 | 2 | Drawable/fixed |
11 | Smart CB | 1600A | Busbar inlet from top/cable inlet from bottom | Dual power switch | 800*600*2200 | 2 | Drawable/fixed |
12 | Smart CB | 2000A | Busbar inlet from top/cable inlet from bottom | Dual power switch | 800*600*2200 | 2 | Drawable/fixed |
13 | Smart CB | 2500A | Busbar inlet from top/cable inlet from bottom | Dual power switch | 1000*800*2200 | 2 | Drawable/fixed |
14 | Smart CB | 3150A | Busbar inlet from top/cable inlet from bottom | Dual power switch | 1000*800*2200 | 2 | Drawable/fixed |
15 | MCCB | 100-225 | Inlet from top/outlet from bottom | Feeder | 800*600*2200 | 12 | Fixed |
16 | MCCB | 225-400 | Inlet from top/outlet from bottom income/bottom outcome | Feeder | 800*600*2200 | 10 | Fixed |
17 | MCCB | 400-630 | Inlet from top/outlet from bottom income/bottom outcome | Feeder | 800*600*2200 | 8 | Fixed |
18 | MCCB | 630-800 | Inlet from top/outlet from bottom income/bottom outcome | Feeder | 800*600*2200 | 6 | Fixed |