AAS Zeeman Absorption Spectrometer
L/CT/T
AAS GGX-910 Introduce
1、Main performance characteristics of the instrument
★1.1 Zeeman background correction technology, full-band background deduction;
1.2 8 lamp automatic turret can preheat eight element lamps at the same time;
★1.3 The patented design of slip ring type 8-lamp turret ,which avoids cable twisting;
★1.4 Lateral Zeeman, constant magnetic field, stable background correction, saving energy and reduce consumption;;
1.5 Automatic peak setting, automatic spectral bandwidth, automatic measurement;
1.6 Automatic gas path, software sets gas flow;
1.7 Titanium burner, corrosion-resistant pre-mixed;
1.8 Can be connected with hydride device to measure arsenic, mercury etc.;
1.9 Safety functions such as self-diagnosis and fault detection。
2、Main Specifications
2.1 Baseline drift(Cu):Static <0.003A/30min;
2.2 The detection limit (Cu):≤0.003μg/mL;
2.3 Precision (Cu):≤0.7%;
2.4 Wavelength repeatability≤0.3nm;Wavelength accuracy≤±0.3nm;
2.5 Spectral bandwidth deviation:≤0.02nm;
3、Optical system
3.1 Wavelength range 180 nm~900nm;
3.2 Spectral bandwidth 0.2、0.4、1.0、2.0nm ;Automatically selectable between four gears;
3.3 1800 scored/mm plane diffraction grating;
3.4 Optimized aberration C-T monochromator, focal length 270mm, short optical path, strong energy;
4、Security function
4.1 Automatic water seal detection, if the water seal lacks water, ignition is prohibited;
4.2 Own waste liquid level detection to prevent waste liquid overflow;
4.3 Own air and acetylene pressure monitoring, the pressure is not enough to prohibit ignition;
4.4 With ignition safety inspection function, complete safety interlock protection device and anti-tempering device
4.5 With flame monitoring, gas can be automatically shut down if the flame is accidentally turned off;
5、Operating software
★5.1 With GMP function, easy to trace;
5.2 Standard series can be automatically configured with automatic dilution function;
5.3 The calibration curve can be arbitrarily selected to ensure accurate measurement when the sample gradient is large;
5.4 With multiple standard blanks and sample blanks, optional, suitable for multiple series of sample measurement;
5.5 Arbitrarily set quality control samples, choose whether to calibrate according to need;
5.6 With slope reset and recalibration function.