Business Type: Manufacturer
Main Products:Electrical WiresIndustrial Power Supply
ID:20120244745
Category: Electrical & Power Energy Wires,Cables & Accessories
MOQ:1000.00 Yard(s)
Un-armoured CableTwin & Earth cableNYY CableN2XH-J power cable RZ1-K cableDouble Insulated CableH05V-U CableH07V-R CableTHHN THWN CableSWA/LSZH Cable
Applications: Power cable suitable for power networks and direct burial, where fire and emissions of smoke and toxic fumes create a serious potential threat. Armoured LSZH power cable to British Standard BS6724 & IEC 60502 suitable for mains power networks
Conductors: Plain annealed stranded copper
Conductor stranding: Class 2 - stranded circular or circular compacted
Insulation: XLPE (Cross linked polyethylene)
Core identification: Brown
Bedding: LSZH (Low smoke zero halogen)
Armour/Protection: AWA (Aluminium wire armour) non-magnetic
Sheath/Jacket: LSZH (Low smoke zero halogen)
Colour: Black
Voltage: 600/1000v
Operating temperature Maximum 90°C
Conductor identification: Brown
Minimum bending radius: 6 x Overall diameter (wherever possible, larger installation radi should be used)
Combustion characteristics: Oxygen index: 35 (Temperature index 280°C)
HCL emission 0.5% in accordance with BSEN50267-1 common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures, determination of the amount of halogen acid gas.
Standard: BS6724: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V, having low emission of smoke and corrosive gases when affected by fire BSEN50267-1 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Apparatus BSEN50267-2-1:Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of the amount of halogen acid gas BSEN50266-1 Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables
IEC 60502: Power cables with extruded insulation and their accessories for rated voltages from 1kV to 30kV
BSEN/IEC60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1: test for vertical flame propagation for a single insulated wire or cable Section 2: procedure for 1kW pre-mixed flame
BSEN61034-2:2005 Measurement of smoke density of cables burned under defined conditions. Test procedure and requirements
Flame Propagation Test to BS EN 60332-1-2:2004 for single cable and BS EN 60332-3-24:2009 (Cat C) for multiple cables