HANGZHOU SECK INTELLIGENT TECHNOLOGY CO.,LTD

Online Supplier

Business Type: Manufacturer

Main Products:Smart Water MeterUltrasonic Water MeterSmart Water Utility Management SystemAutomatic Remote Reading SystemWater Supply and Drainage Products

View on mobile

Bulk Ultrasonic Water Meter - DN50-DN200

ID:21061156489

Tools,Hardware & Instruments Measuring Instruments

FOB Price:US$ 200.000 / Piece(s)

MOQ:100.00 Piece(s)

Product Keywords:

Bulk water meterlarge diameter water meterbig diameter water meterDN50 WATER METERDN200 water meter

Payment Method:

L/CT/TWestern UnionPaypal

Product Category
Tools,Hardware & Instruments > Measuring Instruments
Trademark
SECK
Product Package
wood carton
Specification
each meter in each carton
Place of Origin
CHINA
Port
SHANGHAI

1.      Basic technical parameters

Item

Parameter

Model

LXC-A

Diameter

DN50-DN200

Body   material

Ductile cast iron

Accurate   class

Class B

Maximum   admissible pressure (MAP)

1.6 MPa

Pressure   loss class

△p25

Temp.   class

T50

Sensitivity   of velocity field class

U10/D5(default),U5/D3

Environmental   Class

Class O

Electromagnetic   environment class

Class E2

LCD   display

Cumulative flow m3 and   instantaneous flow rate m3/h display on same screen

Display water temp.: ℃,display   pressure MPa (need to select water meter with pressure sensor)

Batter,In-flow & reverse flow direction,and   error disply

Display   resolution

Cumulative flow (0.001m3), Verification   cumulative flow (0.001L)

Temp.(0.1℃), Pressure(0.01MPa)

Display   range

Cumulative flow:0~99999999.999   m3

Data   communication

GPRS/LoRa/NB-IoT/RS485 (default)

Data   store

Using ferroelectric technology to store   cumulative flow by monthly, automatically store data for the last 12 months,   and store accumulated data for the last 5 years

Power   supply

Battery power DC3.6V,a   battery can be used for 5+1 years

Waterproof   class

IP68

Pulse output mode

Infrared pulse, the pulse equivalent   quantity is set according to the diameter

Communication protocol

Modbus-RTU protocol/CJ. T188 protocol/customize   protocol

 

2.      Measurement performance parameter

Nominal Diameter

DN (mm)

50

65

80

100

150

200

Range

R   (Q3/ Q1)

250

Ratio   Q2/Q1

1.6

Overload   flowrate

Q4(m3/h)

50

78.75

125

200

312.5

500

Permanent flowrate

Q3(m3/h)

40

63

100

160

250

400

Transitional   flowrate

Q2(m3/h)

0.256

0.4032

0.640

1.024

1.600

2.560

Minimum   flowrate

Q1(m3/h)

0.160

0.252

0.400

0.640

1.000

1.600

Start   flowrate

(m3/h)

0.02

0.04

0.04

0.06

0.10

0.20

Accurate   class

Class 2

Maximum   permissible error (MPE)

High flow area(Q2≤Q≤Q4)±2%

Low   flow area(Q1≤Q<Q2)±5%

 

image.png

Fig.2-Dimensional structure drawing

 

Table-1 Dimension

Nominal   diameter

DN(mm)

L1

L2

W

H

Connection

Flange holes number

50

200

130

165

230

Flange

4

65

200

185

232

4

80

225

184

250

8

100

250

205

255

8

150

300

260

296

8

200

350

320

332

12

 


HANGZHOU SECK INTELLIGENT TECHNOLOGY CO.,LTD

Business Type:Manufacturer

Online Supplier